The cryobox tells its own story

When the dry ice runs out, the shipping box and the cryobox inside it warm at very different rates. Watch two hours of a shipment unfold and see why a Pinktail BX™ indicator placed in the cryobox, right beside your cell therapies, is the clearest record of what they actually experienced, during the shipment and long after it.

Ambient
Cutaway of a dry ice shipper An insulated shipper with dry ice surrounding a cryobox of cell therapy vials and a Pinktail BX indicator, with live temperatures for the ambient air, the shipping box and the cryobox. AMBIENT 22 °C IN TRANSIT TIME 3:00 PM +0:00 elapsed 2 IN EPS LID SHIPPING BOX −78.5 °C −20 °C LABEL −78.5 LOGGER −80 °C FREEZER −80 °C CELL THERAPY · 5 × 5 IN CRYOBOX CRYOBOX −78.5 °C INDICATOR Pink Heat dose 0% CUTAWAY · STANDARD EPS DRY ICE SHIPPER, 12 × 12 × 12 IN PAYLOAD
Pinktail BX™ M67C: pink. Cryobox below −67 °C
Dry ice: 15 g remaining
Thermal tint−80 °C+25 °C
Shipping box vs. cryobox
0 °C
Temperature difference between the shipping box air and the cell therapies in the cryobox.
Temperature over time
Ambient 22 °C Shipping box −78.5 °C Cryobox −78.5 °C
What each monitor reports
  • Pinktail BX™In the cryobox, with the cells Pink
  • −20 °C labelIn the shipper No change
  • Data loggerIn the shipper, reading the air −78.5 °C
What’s happening
    01 · Different rates

    The shipping box reacts in minutes

    Once the last dry ice sublimates, the small volume of air inside the shipper has little thermal mass, so its temperature climbs quickly as heat leaks through the walls.

    02 · Thermal lag

    The cryobox follows on its own schedule

    Vials, frozen formulation and the box itself hold far more cold. The cryobox trails the shipping box by tens of degrees, so a reading from the shipper describes the shipper, not the cells.

    03 · The answer

    Measure where the cells are

    A Pinktail BX™ indicator sits in a vial slot inside the cryobox. It accumulates heat exposure right where your therapies are, building faster the warmer the cryobox gets, and changes color once that exposure adds up, giving receiving teams a confident, at-a-glance answer.

    Pinktail BX™ travels with the cryobox

    Labels and data loggers ride in the shipper and come out at receiving. Pinktail BX™ sits in the cryobox beside your cell therapies, so it keeps recording heat exposure through unpacking, freezer storage and every retrieval after that.

    In transport
    After delivery
    PackedCryobox on dry ice
    In transitCourier and dock time
    ReceivedShipper opened, box removed
    On the benchInspection and paperwork
    Freezer storageWeeks, months or years
    RetrievedPulled for use or reshipped
    Pinktail BX™In the cryobox
    Monitoring the cells at every stage
    Data loggerIn the shipper
    Shipper air
    Removed at receiving and sent back for download
    −20 °C labelIn the shipper
    Shipper air above −20 °C
    Discarded with the shipper
    Pinktail BX™
    Data logger
    −20 °C label
    PackedCryobox on dry ice
    In transitCourier and dock time
    ReceivedShipper opened, box removed
    –
    –
    On the benchInspection and paperwork
    –
    –
    Freezer storageWeeks, months or years
    –
    –
    RetrievedPulled for use or reshipped
    –
    –

    Data loggers and labels ride in the shipper and come out at receiving. Pinktail BX™ stays in the cryobox.

    Where an indicator in the cryobox makes the difference

    Shipper monitors describe the shipper. These are the moments when knowing what the cells experienced matters most.

    Every box gets its own answer

    A shipper often carries several cryoboxes, and a box near the lid warms sooner than one buried in dry ice. One logger can’t speak for all of them. An indicator in each cryobox can.

    Decisions based on the cells

    When dry ice runs low, shipper monitors react first, while the cryobox can still be tens of degrees colder. Pinktail BX™ reports the heat the cryobox actually absorbed, so release decisions rest on the product itself.

    Receiving and bench time

    Unpacking, inspection and paperwork all happen after the shipper monitors come out. The indicator keeps accumulating any heat exposure the whole time.

    Months in the freezer

    Power outages, doors left ajar, defrost cycles and freezer transfers. Pinktail BX™ stays active for years and shows any heat exposure the moment the box is opened.

    A glance, at every retrieval

    Each time the box is pulled, its history comes with it. Anyone can check it in a second, with no software, downloads or batteries.

    The temperatures that matter

    Many cell therapies need to stay below −40 °C. A −20 °C label stays unchanged through an excursion to −30 °C. Pinktail BX™ M67C starts accumulating heat above −67 °C, so it responds across the range your product cares about.

    How the options compare

    Pinktail BX™−20 °C labelData logger
    Typical placementIn the cryobox, in a vial slotInside the shipperInside the shipper
    What it measuresThe cryobox, where the cells areShipper airShipper air, unless the probe is in the cryobox
    How it respondsAccumulated heat above −67 °C, faster the warmer it getsA single trip point near −20 °CContinuous time-stamped readings
    Catches excursions between −40 °C and −20 °CYesNoYes, at the probe location
    Keeps monitoring after deliveryYes, through storage and every retrievalNoNo, removed at receiving
    Reading the resultInstant, by eyeInstant, by eyeDownload and software
    Cost to use on every boxLowLowHigh, usually one per shipper
    Time-stamped data recordNoNoYes

    On its own, or alongside a logger

    Pinktail BX™ is the simplest way to know what each cryobox experienced. When your program also needs a time-stamped record of the journey, it pairs naturally with a data logger.

    Pinktail BX™

    An answer in every cryobox

    Replace shipper labels with an indicator that sits with the cells, responds at the right temperatures and stays on duty after delivery.

    • Research, biobank and site-to-site transfers
    • Shipments with several cryoboxes per shipper
    • Long-term freezer storage and repeated retrievals
    • Programs that want box-level confidence at a low cost per box
    A logger tells you what happened to the shipment. Pinktail BX™ tells you what happened to the cells.
    Working in a research lab?See what happens when a box of antibodies is forgotten on the bench after leaving the −80 °C freezer.
    Forgotten on the Bench →
    Storing samples long term?See a year in a shared −80 °C freezer, where the monitor stays in range but each box lives a different life.
    A Year in the Freezer →
    Not storing at −80 °C?Pinktail BX™ also covers −20 °C and −40 °C storage, and we’re developing indicators for −130 °C cryogenic storage. Tell us what you’re protecting.
    Talk to us →
    How we modeled this shipment

    The animation runs a transient heat transfer model, solved second by second, built around a standard dry ice shipper and a 5 × 5 in cryobox. It is an illustrative profile for one common configuration.

    • Shipper: 12 × 12 × 12 in payload space with 2 in expanded polystyrene walls (k ≈ 0.033 W/m·K) inside a corrugated outer carton. Walls are modeled as six conduction layers with their own thermal mass.
    • Dry ice: the final 15 g of pellets at 3:00 PM, holding the payload space at −78.5 °C while it sublimates (571 kJ/kg). Starting heat leak is about 39 W at 22 °C ambient, roughly 6 kg of dry ice per day.
    • Shipping box air: the payload space air, residual CO2 gas and inner liner, lumped as one node coupled to the inner wall by natural convection and radiation.
    • Cryobox: cardboard box with dividers holding 20 × 2 mL cryovials of cell therapy (1.5 mL frozen formulation each). Heat reaches the contents through surface convection, radiation and the box wall, giving a thermal time constant of about 45 minutes.
    • Pinktail BX™ M67C: modeled as its own small thermal mass in a vial slot, tracking the temperature of the cryobox contents. Above −67 °C it accumulates heat exposure based on both time and temperature, responding faster the warmer it gets, and changes color once the accumulated heat reaches its threshold.
    • Cell therapy limit: −40 °C, the temperature receiving teams most often need to confirm was not exceeded.
    • Ambient: held constant at the selected value.

    Every lane, shipper and payload behaves a little differently. Our team can build a time and temperature profile for your exact configuration. Request a profile →

    View the data as a table
    TimeAmbientShipping boxCryoboxDry iceIndicator heat dose

    Put an indicator in every cryobox

    Request a free evaluation kit and see how Pinktail BX™ keeps watch over your cell therapies from packing to retrieval.

    Request Samples